VPG Celtron DLB Alloy Steel, Double-Ended Beam Load Cell

Características

Designed for center mounting and double-link loading, the DLB alloy steel, nickel-plated load cell is a high-accuracy solution for many weighing applications. The DLB is compatible with Unilink/Translink mounting configurations. Available in capacities from 25,000 to 125,000 pounds (11,339.8 to 56,699.1 kilograms). Units are provided with a standard 35 feet/10.6 meters of load cell cable.



Descripción



Especificaciones

Full Scale Output:
3.0 mV/V

Output Resistance:
700 ohms +/- 5

Input Resistance:
770 ohms +/- 10

Material/Finish:
High-alloy steel, nickel plated

Temperature:
Compensated range
14°F to 104°F/-10°C to 40°C

Safe Overload:
150% Full scale

Safe Sideload:
100% Full scale

Rated Excitation:
10 V DC (15 V maximum)

Combined Error:
0.025% Full Scale

Insulation Resistance:
5000 megohms

Seal Type:
Environmentally sealed, IP67

Cable Length:
35 ft/10.6 m

Cable Diameter:
.200 polyurethane jacket 25 k
.305 polyurethane jacket 40 k-125 k

Cable Color Code:
Red ………………….+ Excitation
Black ………………….– Excitation
Green ………………….+ Signal
White ………………….– Signal

Warranty:
One-year limited warranty

Approvals:
FM
NTEP